Controllers
Prices for the 5-model Stanton ST range & other temperature controllers are shown on this page. Down-loadable user handbooks & datasheets for each model in the SPS range are also available. An optional internal over-temperature trip module is available for this range. Controller cables can be found in the Ancillary Equipment section.
The Stanton ST RangeCommon Features
- Alphabetic display for user-friendly operation
- Status display shown during firing
- Attractive wall-mounted enclosure sealed to IP65
- Control range up to 1310°C
- Delayed start facility
- R,K,N & S thermocouple types (field selectable)
- Thermocouple burn-out detection
- Heater element failure detection
- Continuous self-checking of internal operation
- Intelligent power-failure recovery
- Year 2000 compliant
- Optional internal over-temperature trip module (field installable)
| Model | Description |
Price £ Sterling
|
|---|---|---|
| ST312 | The ST312 is a single program controller designed for pottery & ceramics firing. It is fully adjustable with a detailed 6-lamp mimic display. The program comprises 2 ramps followed by a soak. Ramps can be heating or cooling. It executes a controlled ramp to temperature t1 then it executes another controlled ramp to temperature t2. It soaks at t2 for the required period. Natural cooling then follows. |
200 |
| ST314 | The ST314 is a single program controller designed for glass, ceramics & pottery use. The program canhave from 1 to 9 segments. It is fully adjustable with a detailed 5-lamp mimic display & continuous displayof segment number. Each segment comprises of a ramp followed by a soak. Ramps can be heating or cooling. It executes a controlled ramp to the soak temperature where it dwells for the required period then executes the next segment. The end of the program is marked by selecting ‘End’ while entering a ramp rate. Natural cooling then follows. |
215 |
| ST315 | The ST315 is a 9-program controller designed for glass, ceramics & pottery use. Each program can have up to 9 segments. It is fully adjustable with a detailed 5-lamp mimic display & continuous display of program & segment numbers. Each segment comprises of a ramp followed by a soak. Ramps can be heating or cooling. It executes a controlled ramp to the soak temperature where it dwells for the required period then executes the next segment. The end of the program is marked by selecting ‘End’ while entering a ramp rate. Natural cooling then follows. |
225 |
| ST316 | The ST316 is a 9-program controller designed for pottery, ceramics & glass firing. Each program can have from 1 to 9 segments. It is fully adjustable with a detailed 6-lamp mimic display & continuous display of program & segment numbers. Each segment comprises 2 ramps followed by a soak. Ramps can be heating or cooling. It executes a controlled ramp to temperature t1 then it executes another controlled ramp to temperature t2. It soaks at t2 for the required period then executes the next segment. The end of the program is marked by selecting ‘End’ while entering a ramp rate. Natural cooling then follows. |
230 |
| ST501 | The ST501 is a program controller designed for pottery, ceramics & glass firing. Its large illuminated 32 character display makes it easy to set up & use. Setting up is performed using an on-screen menu system and during firing full status information is displayed. |
265 |
Over-Temperature Trip Module
The ST008 is an independent over-temperature trip module designed solely for internal fitment to the ST range of controllers. It is an optional safety device designed to protect kilns from over-firing. It behaves like a resettable heat fuse. Operation of the trip is indicated by an otherwise hidden 'FAULT' legend on the controller front panel

Data Area
More data is available by clicking on the model numbers below. The datasheets & handbooks available below are in Adobe Acrobat (pdf) format. You will need the Adobe Reader to view them. If you do not already have this then it is available here.
| Model | Datasheet | User Handbook |
| ST312 | data312.pdf | user312.pdf |
| ST314 | data314.pdf | user314.pdf |
| ST315 | data315.pdf | user315.pdf |
| ST316 | data316.pdf | user316.pdf |
| ST501 | data501.pdf | user501.pdf |
For Obsolete controllers handbooks click here